![]() |
| Resources | Home > Commercial > Resources > Cleaning Instructions |
Screen Materials Overview Guide to Rear Projection Diffusion Screens Quick Reference Guide To Flexible Screens WP: Perforated Screens WP: Curved Screens WP: Screen and Frame System vs Painted Wall WP: Properties and Performance of Rear Screen Materials WP: Silver 5D Cleaning Instructions FAQ's |
....... |
Description: The Screen Contrast and Brightness Calculator will help you select the proper screen material, the correct projector lumen output and the proper projector focal length to meet your project applications. This calculator will also configure theoretical ANSI checkerboard contrast ratios utilizing difference screen materials for any ambient room light scenarios. Explanation of units of measurement used in this calculator. Foot Lambert units are used to measure screen image brightness. To give you a mental benchmark for foot lambert brightness, a quality movie theater will have a screen brightness of 12 to 16 ft. lamberts in a darkened room. A new fresh plasma will have an output of approximately 40 to 45 foot lamberts and is normally viewed with some room lights present. Lumens are used to measure a projector’s peak light output. When screen size is increased, screen gain is reduced, and/or ambient light is present, then projector lumens must be increased to maintain a pleasing screen image. Foot Candle units are employed to measure the amount of ambient light falling directly on a particular area. This Screen Contrast and Brightness Calculator configures ambient light on the screen wall and also ambient light directly over the viewing area. Under most room lighting designs, there will be considerably less ambient light on the screen wall than directly over viewing area. It is important to configure the ambient light that is entering the viewers eye point. Bright lighting over conference tables and work stations reduce the human eye’s iris opening which in turn allows less screen light to get to the brain. This calculator will configure the ambient light over viewing area and will alert you when a higher lumen projector is required. ANSI Contrast Ratio measures the dynamic range between the peak image brightness and the deepest black level that can be measured on an ANSI back and white checkerboard test pattern. This measurement takes into account the totality of projector output, screen brightness, screen gain and room ambient light reflecting off the screen surface back to the viewer. The ANSI contrast ratio is the single most important number when analyzing a proposed projection system as it is a summary of the performance of the screen image quality. Note: ANSI contrast ratio is not to be confused with projector on-off contrast ratios which are typical stated as 1000 to 1 up to 30000 to 1. Ansi Contrast Ratio Bench Marks: Using Stewart Screen Contrast and Brightness Calculator for Existing Rooms with Stewart Foot Candle Light Meter. To measure ambient light on the screen wall, place the photo sensor disk flat against the wall. Make sure that your body is not blocking the ambient light and casting any shadows on the sensor. Note the Foot Candle measurement. The next measurement is to record the ambient light over the viewing area. Place the photo sensor disk in the up position towards the overhead lightning. Note the Foot candle measurement so that it can be entered into the calculator. Using Stewart Screen Contrast and Brightness Calculator for Rooms that Have Not Been Constructed. -Download the Screen Contrast and Brightness Calculator
|
Email This Print This Page Download the Screen Contrast and Brightness Calculator (Excel) Download the How to Use the Calculator instructions |
|
| Home | About Us | Residential | Commercial | Site Map | Contact Us | ©2011 Stewart Filmscreen |